Fingerprint Access Control Frequently Asked Questions

May 15, 2023
Q: Some users' fingerprint access control often fails to pass the verification. How can this problem be solved?

A: Some of the following situations may cause some employees to use fingerprints or simply cannot use fingerprints for access control:

Fingerprints on some fingers are flattened;

2 There are too many folds on the fingers and often change;

3 Severe peeling on the fingers;

Users with unrecognized fingerprints can delete the fingerprint and register it again, or register another finger.

When registering fingerprints, such users need to choose to use better-quality fingerprints (less creases, lack of skin, and clear fingerprints), try to make the fingers contact the fingerprint collector with a larger area, and do a comparison test after registration; and Register a few more backup fingers.

In addition, the access control system provides a 1:1 comparison method and password function. These employees can be set to use the 1:1 method and password for access control management.

Q: When the access control machine cannot communicate, what are the reasons?

A: Possible reasons are: 1 The communication port is not set correctly, and the selected communication port is not the actual COM port. 2 The baud rate of the computer's communication port is different from the baud rate setting of the attendance machine. 3 The access controller was not connected to the power supply or connected to the computer; 4 The access control was connected but not turned on. 5 The connected terminal number is incorrect. 6 Data lines or converters cannot communicate. 7 The computer's COM port is broken.

Q: After the access controller is powered on, the liquid crystal display is incomplete. Sometimes it only shows half, and sometimes the screen is displayed. How can I solve this problem?

A: The possible reason is 1 bad motherboard; 2 internal characteristics of the LCD. In this case, contact the supplier and return to service.

Q: How to clear the administrator of the access control?

A: You can use the door access computer to communicate with the computer. After the communication is successful, enter the access control management tab page. Click the Clear administrator button to clear the administrator of the access control machine. After the connection is disconnected, you can enter the access control menu mode. Now.

Q: What is the reason why the chiming of the flute sounds when the access control communication is connected?

A: 1 If the above phenomenon occurs when RS-232 communication is used, the baud rate of the computer is inconsistent with the baud rate setting of the attendance machine.

2 If RS-485 communication is used, it may be that the two lines of the converter's communication line are reversed, or the two lines are stuck together.

Q: After the access control machine is turned on, it repeatedly shows 'Please press (leave) finger'. What is the problem? How to solve?

A: The reason for this problem may be:

1 The use of a long time, the collector head surface becomes dirty, or scratches, make the collector head mistakenly believe that the surface is pressed by the finger, and can not pass, so this problem occurs. In this case, adhesive tape can be used to paste the dirt on the surface of the collecting head.

2 The connection of the fingerprint acquisition head is loosened or loosened.

3 motherboard chip is broken.

If the second and third items are two reasons, you need to contact the supplier to apply for warranty.

Q: During the operation of the access control system, there is no problem in downloading the fingerprint and password data. However, when reading the access control record, it prompts a failure or an intermediate error. How can I solve this problem?

A: This situation may be related to the data line, the converter, or the COM port of the computer. At this time, you can reduce the baud rate of the access control machine and the computer. If you set it to 19200 or 9600, read it again.
संपर्क करें

Author:

Ms. Yanjun Chen

ईमेल:

quentin@zecheng.com.cn

Phone/WhatsApp:

+8613602572892

लोकप्रिय उत्पाद
You may also like
Related Categories

इस आपूर्तिकर्ता को ईमेल

विषय:
ईमेल:
संदेश:

Your message must be betwwen 20-8000 characters

होम

Product

Phone

हमारे बारे में

जांच

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

भेजें